Name   Pinebrook North Phase II
Number   Grading 34052
Drawing of Record Submitted   09/12/2005
Electronic Drawing of Record Submitted   09/12/2005
Final Grading Report Submitted  
Date Scheduled  


BUILDING PERMIT RELEASE APPROVALS
Power   08/04/2005 Approved per Dennis Wright
Water   08/04/2005 Corrections Required per Kevin Condie..Valve need to be up to grade and concrete collar around meter setters. Need water to hydrants. 08/10/2005 Corrections required per Kevin Condie. Valve on Indian Hills Dr need to be at subgrade 09/07/2005 Corrections required per Kevin Conide.. NOT READY.. Valve need to be raised in project and on Indian Hills, check wire, fire hydrant collar need to run into curb, clean hydrants and paint,meter for church need collar and w/rebar need to check meter setters.. Not ready 09/08/2005 Approved per Kevin Condie.. Permits Only.. Not a Final
Waste   08/08/2005 Corrections required per Shayne D. No protection in bottom of manholes. 09/07/2005 Corrections required per Glen Garland..Raising M/H's for collaring -- not collard yet.. Missing "S" marks 2 locations, need drawing of record. 09/08/2005 Approved per Glen Garland for permits only
Engineering   08/04/2005 Correctiosn Required per Larry Henderson.. Complete base, ashphalt and SW 08/10/2005 Corrections required per Larry Henderson.. Project not complete 09/08/2005 Approved per Larry Henderson
City Development Engineer   09/08/2005 Approved per Jay Sandberg..Permits Only
Landscaping  


FINAL INSPECTION RELEASE APPROVALS
Power   09/21/2005 Approved per Dennis W. 11/2/06 1 year warranty Approved per Dennis Wright.
Water   09/16/2005 Corrections required per Kevin Condie 1. No arrow in concrete collars, 2. No Number in concrete collars (pipe Size..)3. Meter for church hs no collar around it 4. Clean and paint hydrants.5. Need to check hydrant valve and wire. 6. Meter pad on lot 3 is broken. 10/21/2005 Approved per Kevin Condie 11/7/06 1 year warranty Approved per Kevin Condie.
Waste   09/15/2005 Corrections required per Glen Garland.No "S" marks in curb on lots # 5 and 9 10/20/2005 Approved per Glen Garland 11/1/06 1 year warranty - Approved per Glen Garland.
Engineering   09/15/2005 Corrections required per Larry H.. Backfill behind curb and sidwalk,complete sidewalk on Indian Hills, install street lights,seal cracks in curb, trim expansion joints,remove block and material from street, complete entry. install monuments, remove construction debris, cover inlet lot 8 to prevent trash in line 12/12/2005 Approved per Larry Henderson 1/2/07 1 year warranty - Corrections required per Brandon Wright. Sunken and cracked concrete around meter boxes. Cracked curbs.
City Development Engineer   09/26/2005 Corrections required per Jay Sandberg.. Final plat not signed by City Attty. or City Engineer 12/23/2005 Approved per Jay Sandberg 11/14/06 - 1 year warranty - Approved per Ken B.
Landscaping   10/18/2005 Approved per Mark Bradley.. N/A ..City Maintained Site along Indian Hills Drive 11/08/2005 Approved per Doug W. N/A 11/14/06 - 1 year warranty - Approved per Ken B.


General Comments